CF567B.Berland National Library

普及/提高-

通过率:0%

AC君温馨提醒

该题目为【codeforces】题库的题目,您提交的代码将被提交至codeforces进行远程评测,并由ACGO抓取测评结果后进行展示。由于远程测评的测评机由其他平台提供,我们无法保证该服务的稳定性,若提交后无反应,请等待一段时间后再进行重试。

题目描述

Berland National Library has recently been built in the capital of Berland. In addition, in the library you can take any of the collected works of Berland leaders, the library has a reading room.

Today was the pilot launch of an automated reading room visitors' accounting system! The scanner of the system is installed at the entrance to the reading room. It records the events of the form "reader entered room", "reader left room". Every reader is assigned a registration number during the registration procedure at the library — it's a unique integer from 11 to 10610^{6} . Thus, the system logs events of two forms:

  • "+ rir_{i} " — the reader with registration number rir_{i} entered the room;
  • "- rir_{i} " — the reader with registration number rir_{i} left the room.

The first launch of the system was a success, it functioned for some period of time, and, at the time of its launch and at the time of its shutdown, the reading room may already have visitors.

Significant funds of the budget of Berland have been spent on the design and installation of the system. Therefore, some of the citizens of the capital now demand to explain the need for this system and the benefits that its implementation will bring. Now, the developers of the system need to urgently come up with reasons for its existence.

Help the system developers to find the minimum possible capacity of the reading room (in visitors) using the log of the system available to you.

输入格式

The first line contains a positive integer nn ( 1<=n<=1001<=n<=100 ) — the number of records in the system log. Next follow nn events from the system journal in the order in which the were made. Each event was written on a single line and looks as "+ rir_{i} " or "- rir_{i} ", where rir_{i} is an integer from 11 to 10610^{6} , the registration number of the visitor (that is, distinct visitors always have distinct registration numbers).

It is guaranteed that the log is not contradictory, that is, for every visitor the types of any of his two consecutive events are distinct. Before starting the system, and after stopping the room may possibly contain visitors.

输出格式

Print a single integer — the minimum possible capacity of the reading room.

输入输出样例

  • 输入#1

    6
    + 12001
    - 12001
    - 1
    - 1200
    + 1
    + 7
    

    输出#1

    3
  • 输入#2

    2
    - 1
    - 2
    

    输出#2

    2
  • 输入#3

    2
    + 1
    - 1
    

    输出#3

    1

说明/提示

In the first sample test, the system log will ensure that at some point in the reading room were visitors with registration numbers 11 , 12001200 and 1200112001 . More people were not in the room at the same time based on the log. Therefore, the answer to the test is 3.

首页